Double Shaver Plug Adaptor UK with 2 USB, TESSAN 2 Pin to 3 Pin Adapter Plug Socket for Bathroom Electric Razor, Toothbrush and EU US Plugs, 10A Fused White

£9.9
FREE Shipping

Double Shaver Plug Adaptor UK with 2 USB, TESSAN 2 Pin to 3 Pin Adapter Plug Socket for Bathroom Electric Razor, Toothbrush and EU US Plugs, 10A Fused White

Double Shaver Plug Adaptor UK with 2 USB, TESSAN 2 Pin to 3 Pin Adapter Plug Socket for Bathroom Electric Razor, Toothbrush and EU US Plugs, 10A Fused White

RRP: £99
Price: £9.9
£9.9 FREE Shipping

In stock

We accept the following payment methods

Description

When securing wires ensure that the retaining screw that holds the wire in place is tightened fully and that it has plenty of bare wire to clamp down on to. As we have mentioned above, when running down a wall to a power supply unit such as this the cable will need to run vertically down in a straight line to comply with regulations. Once this is done, a minor works certificate is then issued to prove the installation has been carried out correctly. In the UK there are very strict rules on who can and cannot do certain electrical jobs. This is mainly due to the fact that, as we all know, electricity is extremely dangerous and when working on or around it, it is essential that you know what you are doing. If either of the above are ignored, if any issues occur and you cannot produce a certificate for the works then there is a good chance that your home insurance will be invalid, so it certainly isn’t worth the risk.

Once all the wires have been connected, the face plate is then screwed on to the pattress box, fixing it in place. Using electrical equipment in bath or shower rooms has always needed great care to ensure safety due to the obvious risks of mixing water and electricity. Zone 2 – the area beyond zones 0 and 1, 0.6m horizontally and up to 2.25m vertically. Zone 2 also includes any recessed window with a sill next to the bath and also around the wash basin

Should a Shaver Socket be Connected to a Fused Connection?

Ideally look for a model with double wound isolating transformer, integral overload protection and shutters on the plug inlets to prevent any accidental splashing. If no supplies are this conveniently placed then it may be that you have to take up some floorboards in an above room and run your supply from here. The cable is then normally capped (covered with a protective UPVC capping) or run through some UPVC trunking/pipe to protect it and hold it in place.

In both cases, the cables are run down through the ceiling and down a chase cut into the wall to run to both locations Once in place the cable was then tested to ensure there were no breaks etc. This is a necessary step as once the cable is filled over it’s a nightmare to have to dig it all out if it’s damaged. All wires are then set into the wall and capped with protective sleeving and then all chases are filled, smoothed off and the either painted or tiled over. Once a suitable supply has been found the next task is to isolate the supply to the circuit you are using! If in any doubt, the power to the entire house is turned off.As previously mentioned, if you are sing a lighting circuit make sure it’s RCD protected. If it isn’t then you can’t use it.

The cable was then secured in place using UPVC capping to not only hold it but also protect it from any damage that might from any potential future work. In this example here we are using an existing lighting circuit so a 1mm twin and earth cable is run out from the top of the ceiling rose, down through the ceiling and down a chase that was cut into the wall.Wall chased out and cable placed in chase and protective UPVC pipe Step 3 – Install Fused Connection Unit (FCU) Zone 0 – the interior of the bath or shower which can hold water. No appliances should be installed here period!



  • Fruugo ID: 258392218-563234582
  • EAN: 764486781913
  • Sold by: Fruugo

Delivery & Returns

Fruugo

Address: UK
All products: Visit Fruugo Shop